We
are one of the leading manufacturer and exporter of nitrous oxide plants.
Our Nitrous Oxide plants are very safe and economical plants with an
efficient Generation system which reduces power consumption and adds on to
safety. A storage battery assembly for separation of Nitrogen is another
safety feature with the Universal plant. The gas manufactured conforms to
Indian Pharmacopia, US & European standards and is stored in liquid
state which can be directly filled into cylinder. | Chemical formula | N2O |
| Molecular weight | 44.0128 |
| Specific volume at 15°C and 1 atm | 0.533m3/kg |
| Specific gravity (air=1) | 1.5297 |
| Density at 15°C and 1 atm | 1.877kg/m3 |
| Specific heat at 15°C and 1 atm | 0.866kj/kg (°C) |
Production Process
Nitrous Oxide is produced by heating Ammonium Nitrate to a temperature of 250 Deg.c. Ammonium Nitrate is decomposed in the process to give a mixture of Nitrous Oxide & super heated steam. At the same time impurities are produced including Ammonium Nitrate fumes, Nitrogen & other oxides of Nitrogen. The steam & impurities are removed by scrubbing with water, caustic soda and sulfuric acid in sequence Nitrogen present in traces is removed by bleeding from the top of storage vessels where Nitrous Oxide is stored, after compression by a compressor. Capacities 8 - 24 cum/hr .
Salient Features Of Our Nitrous Oxide Plants
- Product purity meets world standards.
- Special safety features incorporated in the plant.
- Stainless Steel Construction.
- Decomposer and Melter separately mounted and controlled.
- Online moisture meter installed.
- Complete laboratory equipment for testing of gas is provided with plant as standard accessory.
- Double drier provided.
- Skid mounted, modular design occupies less space.
Purity
Purity is minimum 99.9% and it very well meets the European and American Pharmaceutical standards
Cylinder Testing Station
A cylinder testing station (optional) can be provided to test cylinders. Similarly, a vacuum pump can be also provided to evacuate the cylinders received from customers which might be containing some left over impure nitrous oxide. A small laboratory is a must to maintain complete analysis of batch produced in the plant. The plant is automatic and required only 2 persons to operate per shift besides a chemist.
Scope of Supply